Cavity Wall Insulation

Bonded Bead Cavity Wall Insulation
Approximately 25% of heat is lost through the walls of a house. More heat is lost through the walls of a house than through any other part of the building envelope. Cavity Wall Insulation is one of the most cost-effective energy efficiency measures in the home.Composition & Durability
The polystyrene used for Cavity Wall Insulation is in the form of virgin pre-formed bead. The bead is combined with a binding agent or adhesive at the time of injection. Polystyrene bead are produced to a specified size and density which remains unaltered during the installation process.The materials are produced under strict quality control to ensure compliance with the performance requirement of the Irish Agrément Board.
The installation must be carried out in accordance with the relevant IAB Certificate, their surveillance scheme, the System Suppliers installation Manual and to best practice.
Once installed, the bead filling in the cavity will remain an effective insulant for the life of the building and will require no further maintenance.

Properties:
- Thermal Conductivity: The k value of White expanded polystyrene bead should be taken as 0.033W/m C - 0.040 W/m C (ref. individual IAB Certs)
- Density: A typical installed density is 12kgm3 +/- 2kgm3 (ref. individual IAB Certs)
- Fire: The use of polystyrene bead for cavity wall insulation does not prejudice the fire resistance properties of the wall.
- Water: The material is resistant to water penetration and will not transmit water across the cavity by capillary action or from below dpc level. Any rainwater penetrating the outer leaf will drain harmlessly to the footings. The product is not designed to be a water vapour barrier
Application
- Survey: A pre-installation assessment is carried out to determine the suitability of the property for cavity wall insulation.
- Preparation: Internal and external checks are carried out by the Technician prior to installation. Injection holes are drilled in the external wall of the cavity as specified by the relevant BBA Certificate and System Suppliers manual. Typically holes are drilled around the upper part of the building only and below windows and lintels. The cavity at any party wall line is sealed with a closure approved by the IAB for the purpose.
- Installation: The polystyrene beads are injected into the cavity via an injection gun in a specified sequence to ensure a complete fill of the cavity.
- Making good: Following the installation the injection holes are made good to match the original wall surface as closely as possible.
- Post Installation Check: All fuel-burning appliances and their flues or source of air supply are checked to confirm their effectiveness